We introduce you to Horizontal/Vertical Discharge Fan Forced Suspended Unit Heater with 5000 / 3700 Watts and 17.1 / 12.8 BTU/Hr. TPI HF1B5105N comprises of fan over-ride that purges unit of residual heat at shutdown, automatic reset type limit to de-energize the heater should an over-temperature situation occur and totally enclosed, 1-speed, 1-phase, permanently lubricated thermally protected motor with unit bearings. Louvers are individually adjustable for directional control of air flow up to 15 deg. from straight horizontal.
| Horizontal/Vertical Discharge Fan Forced Suspended Unit Heater - TPI HF1B5105N Specifications |
|---|
| BTU | 17.1 / 12.8 |
|---|
| Wattage | 5000 / 3700 W |
|---|
| Voltage | 240 / 208 V |
|---|
| Control Volts | 240 / 208 V |
|---|
| Product Weight | 25 Lbs. |
|---|
| Product Dimensions | 14-15/32"W x 6-1/2"D x 17-3/4"H |
|---|
| Phase | 1 |
|---|
| Temperature Rise | 40 F |
|---|
| CFM | 400 |
|---|
| Amperage | 20.9 / 18.1 |
|---|
| Air Throw | 12' |
|---|
| Recommended Mounting Height | 9' Hortz. 9' Vert. |
|---|
| UPC | 686334645560 |
|---|
Horizontal/Vertical Discharge Fan Forced Suspended Unit Heater - TPI HF1B5105N Features:
CONSTRUCTION: - 18 ga. steel cabinet with powder coated finish and control compartment housing a master terminal board with a hinged and latched access door, simplifying wiring, installation & maintenance
HEATING ELEMENT: - Spiral fin steel element with continuously brazed steel fins formed to allow side draw through air flow
OVERHEAT PROTECTION: - Equipped with automatic reset type limit to de-energize the heater should an over-temperature situation occur.
FAN and MOTOR: - Totally enclosed, 1-speed, 1-phase, permanently lubricated, thermally protected motor with unit bearings
- Fan over-ride purges unit of residual heat at shutdown
LOUVER ASSEMBLY: - Louvers are individually adjustable for directional control of air flow up to 15 deg. from straight horizontal
- Optional diffusers available for down flow (vertical discharge) applications
TEMPERATURE CONTROLS: - Optional low voltage and line voltage thermostats available with an adjustable temperature range of 50-90 deg. F
INSTALLATION: - It can be mounted for horizontal or vertical discharge
- Suggested for applications up to 6000 feet
FIELD INSTALLED OPTIONS: - In-Built or wall mounted temperature control thermostats - low or line voltage
- Summer fan switch to operate the fan only.
- Power disconnect switch
- Heat stratification thermostat
- cETLus listed